Drainage and Utilities CONNECT Edition Help

Conduit-Infiltration/Inflow and Seepage

Conduit-Infiltration/Inflow and Seepage Attributes

Attribute Description
Infiltration Load Type Lets you select the type of infiltration load associated with the selected conduit. You can select Pipe Length , Pipe Rise-Length , Pipe Surface Area , Count Based , Hydrograph, Pattern Load , or None .
Flow (Infiltration) Lets you enter any additional infiltration flow at the selected conduit.
Infiltration Loading Unit Lets you select the unit of measure for the infiltration load. To use this field, you must set the Infiltration Loading Type to Pipe Length , Pipe Rise-Length , or Pipe Surface Area .
Infiltration Rate per Loading Unit The infiltration rate per load for the selected conduit. To use this field, you must set the Infiltration Loading Type to Pipe Length , Pipe Rise-Length , Pipe Surface Area , or Count Based .
Infiltration Unit Count The infiltration unit count for the selected conduit. To use this field, you must set the Infiltration Loading Type to Count Based .
Hydrograph Curve Lets you define the infiltration load for the selected conduit as a hydrograph. Click the Ellipsis (…) button in this field to display the Hydrograph Curve dialog box, where you can define the Time vs. Flow data points that make up the hydrograph curve. To use this field, you must set the Infiltration Loading Type to Hydrograph .
Infiltration Pattern Lets you define the infiltration load as a pattern. You can select Fixed (the default value), an existing pattern, or Edit Pattern . When you select Edit Pattern, the Patterns dialog box appears. To use this field, you must set the Infiltration Loading Type to Pattern Load .
Flow (Infiltration Base) The base infiltration flow for the selected conduit. To use this field, you must set the Infiltration Loading Type to Pattern Load .